Zhejiang, China
SAINTBOND single point load cell
AM649D single point load cell
Weighing
Resistance Sensor
Other
single point load cell
50~2500KG
Aluminum
IP65
9VDC~12VDC
0.02%F.S
Welcome
OEM&ODM
1pcs per type per capacity
OEM & ODM Manufacture
60/150/250/350/500kg customize aluminum small thread single point load cell
Size: 150x40x45(mm) Thread hole:8-M8
It uses 4-core shielded cable (φ5×1500mm). The length of the cable can be adjusted according to clients' request,
but we suggest to use this standard length to ensure the output precision
Technical Parameter:
Rated Load: | 60/100/150/200/250/300/350/500kg | ||
Comprehensive Error: | 0.017&0.02%F.S | Insulation Resistance: | ≥5000MΩ(100VDC) |
Rated Output: | 2±0.1mV/V | Excitation Voltage: | 9VDC~12VDC |
Non-Linearity: | 0.017&0.02%F.S | Compensated Temp. Range: | -10℃~+40℃ |
Hysteresis: | 0.017&0.02%F.S | Use Temp. Range: | -20℃~+60℃ |
Repeatability: | 0.01%F.S & 0.02%F.S | Temp. Effect On Zero: | 0.017&0.03%F.S/10℃ |
Creep: | & 0.02%F.S/10min | Temp. Effect On Span: | 0.014&0.02%F.S/10℃ |
Zero Balance: | ±1%F.S | Safe Overload: | 120% |
Input Resistance: | 405±10Ω | Ultimate Overload: | 150% |
Output Resistance: | 350±3Ω | Defense Class: | IP65 |
60/150/250/350/500kg customize aluminum small thread single point load cell
Size: 150x40x45(mm) Thread hole:8-M8
It uses 4-core shielded cable (φ5×1500mm). The length of the cable can be adjusted according to clients' request,
but we suggest to use this standard length to ensure the output precision
Technical Parameter:
Rated Load: | 60/100/150/200/250/300/350/500kg | ||
Comprehensive Error: | 0.017&0.02%F.S | Insulation Resistance: | ≥5000MΩ(100VDC) |
Rated Output: | 2±0.1mV/V | Excitation Voltage: | 9VDC~12VDC |
Non-Linearity: | 0.017&0.02%F.S | Compensated Temp. Range: | -10℃~+40℃ |
Hysteresis: | 0.017&0.02%F.S | Use Temp. Range: | -20℃~+60℃ |
Repeatability: | 0.01%F.S & 0.02%F.S | Temp. Effect On Zero: | 0.017&0.03%F.S/10℃ |
Creep: | & 0.02%F.S/10min | Temp. Effect On Span: | 0.014&0.02%F.S/10℃ |
Zero Balance: | ±1%F.S | Safe Overload: | 120% |
Input Resistance: | 405±10Ω | Ultimate Overload: | 150% |
Output Resistance: | 350±3Ω | Defense Class: | IP65 |
Optimization Design of Diaphragm in Welding Sealed Load Sensor
Technical Characteristics and Application Analysis of Several Weighing Load Cells
High temperature weighing load cell with cylindrical spiral spring inductance coil
Analysis of the lateral load resistance ability of cantilever shear beam type weighing load cells
RC、RL The Application of Inert Circuit in the Manufacturing of Weighing Instruments and Load Cell
The role and development trend of the manufacturing process for weighing Load Cell
Electric forklift technology development and research direction
Advantages and disadvantages of resistance strain type load cell
Manufacturing link of resistance strain type weighing sensor
What are the key points for selecting explosion-proof load cells?
0 Comment