Zhejiang, China
SAINTBOND Safe Limiter Overload Pin Load Cell
LC703W03 Safe Limiter Overload Pin Load Cell
Weighing industry
Resistance Sensor
Digital Sensor
Safe Limiter Overload Pin Load Cell
LED or LCD
Alloy Steel, Stainless Steel
Welcome
OEM&ODM
110V or 220v
15V DC
1pcs
Factory Latest Custom Steel wire rope Sensor Stainless Steel Safe Limiter Overload Pin Load Cell
Cap./Size | φ1 | H1 | H2 | L1 | L2 | L3 | L4 | L5 | L6 |
2~5t | 35 | 11.5 | 16 | 105 | 20 | 12 | 12 | 35 | 6.3 |
10t | 50 | 20 | 22.5 | 152 | 30 | 18 | 18 | 48 | 10.5 |
20t | 65 | 22.5 | 28.5 | 190 | 32 | 20 | 25 | 65 | 10.5 |
40t | 85 | 22.5 | 28.5 | 256 | 36 | 35 | 28 | 89 | 12.5 |
70t | 100 | 34 | 35 | 328 | 40 | 50 | 32 | 120 | 15 |
Rated Load: | 2/5/10/20/40/70t | Operating Temperature Range: | -30~+70℃ |
Sensitivity: | (1.0±0.1%) m V/V | Maximum Safe Over Load: | 150%F.S |
Combined Error: | ±0.5% F.S | Ultimate Over Load: | 180%F.S |
Creep Error(30min): | ±0.05% F.S | Recommend Excitation Vol.: | 10~12V DC |
Zero Balance: | ±1% F.S | Maximum Excitation Voltage: | 15V DC |
Temp. Effect On Zero: | ±0.05% F.S/10℃ | Sealing Class: | IP67 |
Temp. Effect On Span: | ±0.05% F.S/10℃ | Element Material: | Alloy Steel,StainlessSteel |
Input Resistance: | 750±5Ω | Insulation Resistance: | ≥5000MΩ |
Output Resistance: | 702±3Ω | Citation: | GB/T7551-2008/OIMLR60 |
Cable: | Length=L:5m(2~5t);10m(10~20t);16m(30~70t) | ||
Mode Of Connection: | Red(Input+),Black(Input-),Green(Output+),White(Output-) |
Wireless Frequency: | 430~485MHz |
Wireless Distance: | Min:800m(In Open Area) |
A/D Conversion Rate: | ≥50times/seconds |
Operating Temp. Range: | -20~+80℃ |
Operating Humidity: | ≤85%RH under 20℃ |
Battery Life: | ≥50 hours |
Non-Linearity: | 0.01%F.S |
Stable Time: | ≤5 Seconds |
Citation: | GB/T7551-2008/ OIML R60 |
Factory Latest Custom Steel wire rope Sensor Stainless Steel Safe Limiter Overload Pin Load Cell
Cap./Size | φ1 | H1 | H2 | L1 | L2 | L3 | L4 | L5 | L6 |
2~5t | 35 | 11.5 | 16 | 105 | 20 | 12 | 12 | 35 | 6.3 |
10t | 50 | 20 | 22.5 | 152 | 30 | 18 | 18 | 48 | 10.5 |
20t | 65 | 22.5 | 28.5 | 190 | 32 | 20 | 25 | 65 | 10.5 |
40t | 85 | 22.5 | 28.5 | 256 | 36 | 35 | 28 | 89 | 12.5 |
70t | 100 | 34 | 35 | 328 | 40 | 50 | 32 | 120 | 15 |
Rated Load: | 2/5/10/20/40/70t | Operating Temperature Range: | -30~+70℃ |
Sensitivity: | (1.0±0.1%) m V/V | Maximum Safe Over Load: | 150%F.S |
Combined Error: | ±0.5% F.S | Ultimate Over Load: | 180%F.S |
Creep Error(30min): | ±0.05% F.S | Recommend Excitation Vol.: | 10~12V DC |
Zero Balance: | ±1% F.S | Maximum Excitation Voltage: | 15V DC |
Temp. Effect On Zero: | ±0.05% F.S/10℃ | Sealing Class: | IP67 |
Temp. Effect On Span: | ±0.05% F.S/10℃ | Element Material: | Alloy Steel,StainlessSteel |
Input Resistance: | 750±5Ω | Insulation Resistance: | ≥5000MΩ |
Output Resistance: | 702±3Ω | Citation: | GB/T7551-2008/OIMLR60 |
Cable: | Length=L:5m(2~5t);10m(10~20t);16m(30~70t) | ||
Mode Of Connection: | Red(Input+),Black(Input-),Green(Output+),White(Output-) |
Wireless Frequency: | 430~485MHz |
Wireless Distance: | Min:800m(In Open Area) |
A/D Conversion Rate: | ≥50times/seconds |
Operating Temp. Range: | -20~+80℃ |
Operating Humidity: | ≤85%RH under 20℃ |
Battery Life: | ≥50 hours |
Non-Linearity: | 0.01%F.S |
Stable Time: | ≤5 Seconds |
Citation: | GB/T7551-2008/ OIML R60 |
Optimization Design of Diaphragm in Welding Sealed Load Sensor
Technical Characteristics and Application Analysis of Several Weighing Load Cells
High temperature weighing load cell with cylindrical spiral spring inductance coil
Analysis of the lateral load resistance ability of cantilever shear beam type weighing load cells
RC、RL The Application of Inert Circuit in the Manufacturing of Weighing Instruments and Load Cell
The role and development trend of the manufacturing process for weighing Load Cell
Electric forklift technology development and research direction
Advantages and disadvantages of resistance strain type load cell
Manufacturing link of resistance strain type weighing sensor
What are the key points for selecting explosion-proof load cells?
0 Comment