Availability: | |
---|---|
Quantity: | |
PDF Export | |
Zhejiang, China
SAINTBOND melt pressure transducer 4-20ma
PT124 / PT124B melt pressure transducer 4-20ma
melt pressure transducer 4-20ma
Aluminum-alloy
≥2000MΩ,100VDC
Welcome
OEM&ODM
1pcs per type per capacity
20~45 DAYS
OEM & ODM Manufacture
6 gilded pin / 5 pin
Great durability applying petro-chemical special occasions melt pressure transducer 4-20ma
PARAMETERS: |
Capacity Range:0-1-150MPa |
Comprehensive Precision:0.1%FS, 0.2%FS, 0.3%FS, 0.5%FS, 1.0%FS |
Output Signal: 2mV/V; 2.5mV/V; 3.3mV/V; 4~20mA; 0~5V; 1~5V; 0~10V |
Use Temp Range:-10~200℃-400℃ |
Excitation Voltage: Transducer =10V (6~12)V;Transmitter=24V (9~36)V;Transmitter=15~36V |
Insulation Resistance: ≥2000MΩ,100VDC |
Eletric Connection: 6 gilded pin / 5 pin |
Thread connection:1/2-20UNF or Others |
EXAMPLE: PT111 - 35M - 01 - C - G - 6 / 18 - J - W | ||||||||||
PT1 | 11 | 35 | M | 01 | C | G | 6 | 18 | J | W |
11 | Models | |||||||||
35 | Capacity(Noted by number) | |||||||||
M | Pressure Meassure ( P=Psi, B=Bar, M=MPa ) | |||||||||
01 | Output Signal (01=2mV/V, 02=2.5mV/V, 03=3.3mV/V, 04=4~20mA, 05=1~5V, 06=0~5V, 07=0~10V ) | |||||||||
C | Precision (%FS)(B=0.2, C=0.3,D=0.5, E=1.0 ) | |||||||||
G | Thread Connection (F=M12×1,G=M14×1.5,H=1/2-20, L=M18×1.5,M=M22×1.5, N=M28×1.5, P=G3/4, Q=G3/8 ) | |||||||||
6 | Length of Rigid Stem( 2 =2.36“, 60mm,6=6”, 152mm) | |||||||||
18 | Length of Flexible Tube(18=18“, 460mm,blank= none) | |||||||||
J | Thermcouple option (J, K, E, PT100 ) | |||||||||
W | Electric connection(W=5pin, L=6pin ) |
ABSTRACT:
Insulated by rigid or flex tube.Applying to pressure measuring and controlling of Rubber,
Chemical fiber, Petro-chemical and other special occasions.
Great durability applying petro-chemical special occasions melt pressure transducer 4-20ma
PARAMETERS: |
Capacity Range:0-1-150MPa |
Comprehensive Precision:0.1%FS, 0.2%FS, 0.3%FS, 0.5%FS, 1.0%FS |
Output Signal: 2mV/V; 2.5mV/V; 3.3mV/V; 4~20mA; 0~5V; 1~5V; 0~10V |
Use Temp Range:-10~200℃-400℃ |
Excitation Voltage: Transducer =10V (6~12)V;Transmitter=24V (9~36)V;Transmitter=15~36V |
Insulation Resistance: ≥2000MΩ,100VDC |
Eletric Connection: 6 gilded pin / 5 pin |
Thread connection:1/2-20UNF or Others |
EXAMPLE: PT111 - 35M - 01 - C - G - 6 / 18 - J - W | ||||||||||
PT1 | 11 | 35 | M | 01 | C | G | 6 | 18 | J | W |
11 | Models | |||||||||
35 | Capacity(Noted by number) | |||||||||
M | Pressure Meassure ( P=Psi, B=Bar, M=MPa ) | |||||||||
01 | Output Signal (01=2mV/V, 02=2.5mV/V, 03=3.3mV/V, 04=4~20mA, 05=1~5V, 06=0~5V, 07=0~10V ) | |||||||||
C | Precision (%FS)(B=0.2, C=0.3,D=0.5, E=1.0 ) | |||||||||
G | Thread Connection (F=M12×1,G=M14×1.5,H=1/2-20, L=M18×1.5,M=M22×1.5, N=M28×1.5, P=G3/4, Q=G3/8 ) | |||||||||
6 | Length of Rigid Stem( 2 =2.36“, 60mm,6=6”, 152mm) | |||||||||
18 | Length of Flexible Tube(18=18“, 460mm,blank= none) | |||||||||
J | Thermcouple option (J, K, E, PT100 ) | |||||||||
W | Electric connection(W=5pin, L=6pin ) |
ABSTRACT:
Insulated by rigid or flex tube.Applying to pressure measuring and controlling of Rubber,
Chemical fiber, Petro-chemical and other special occasions.
Optimization Design of Diaphragm in Welding Sealed Load Sensor
Technical Characteristics and Application Analysis of Several Weighing Load Cells
High temperature weighing load cell with cylindrical spiral spring inductance coil
Analysis of the lateral load resistance ability of cantilever shear beam type weighing load cells
RC、RL The Application of Inert Circuit in the Manufacturing of Weighing Instruments and Load Cell
The role and development trend of the manufacturing process for weighing Load Cell
Electric forklift technology development and research direction
Advantages and disadvantages of resistance strain type load cell
Manufacturing link of resistance strain type weighing sensor
What are the key points for selecting explosion-proof load cells?