Availability: | |
---|---|
Quantity: | |
PDF Export | |
Model | Size(A×B×C) (mm) | Capacity (Double Pads for One Axel) | Description(Each Pad) |
AS002 | 350×350×35 | 1000/2000/3000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:500/1000/1500Kg |
400×500×56.5 | 3000/5000/6000/10000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:1500/2500/3000/5000Kg | |
450×700×56.5 | 10000/20000/30000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:5000/10000/15000Kg | |
500×900×56.5 | 20000/30000/40000Kg | 4pcs LC348 LoadCell,10m Cable |
Product Parameters | ||
Rated load:1/2/3/5/6/10/20/30/40T | Compensated temp.range(℃): -10~+50 | |
Dynamic error (%F.S): 3 (5~10km/h) | Static error (%F.S):0.1~0.3 | |
Static comprehensive error(%F.S): 0.1~0.5 | Insulation resistance(MΩ): ≥5000(100VDC) | |
Rated output(mV/V): 1.0±0.1 | Use temp.range(℃): -30~+80 | |
Non-linearity(%F.S): 0.2 | Temp.effect on zero(F.S/10℃): 0.03 | |
Error on corners(%F.S): 0.2 | Temp.effect on span(F.S/10℃): 0.05 | |
Repeatariy(%F.S): 0.05 | Safe overload(%): 120 | |
Zero balance(%F.S): ±1 | Ultimate overload(%): 150 | |
Excitation voltage(VDC): 9~15 | Net weight(kg): 45 | |
Recommended voltage(V): 10 | Defend grade: IP66 |
Wireless Specification | ||
A/D conversion method | Σ-Δ 24bit | |
Input signal range | –19.5mV~19.5mV | |
Load cell excitation | DC 5V | |
Max. connection number of load cell | 1~4 | |
Load cell connection mode | 4 wire | |
Operating temperature | -10 °C ~40 °C | |
Allowable working temperature | -40 ° C ~ 70 ° C | |
Wireless transmission frequency | 430MHz to 470MHz | |
Wireless transmission distance | 800 meters (In Open Place) |
Model | Size(A×B×C) (mm) | Capacity (Double Pads for One Axel) | Description(Each Pad) |
AS002 | 350×350×35 | 1000/2000/3000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:500/1000/1500Kg |
400×500×56.5 | 3000/5000/6000/10000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:1500/2500/3000/5000Kg | |
450×700×56.5 | 10000/20000/30000Kg | 4pcs LC348 LoadCell,10m Cable Capacity:5000/10000/15000Kg | |
500×900×56.5 | 20000/30000/40000Kg | 4pcs LC348 LoadCell,10m Cable |
Product Parameters | ||
Rated load:1/2/3/5/6/10/20/30/40T | Compensated temp.range(℃): -10~+50 | |
Dynamic error (%F.S): 3 (5~10km/h) | Static error (%F.S):0.1~0.3 | |
Static comprehensive error(%F.S): 0.1~0.5 | Insulation resistance(MΩ): ≥5000(100VDC) | |
Rated output(mV/V): 1.0±0.1 | Use temp.range(℃): -30~+80 | |
Non-linearity(%F.S): 0.2 | Temp.effect on zero(F.S/10℃): 0.03 | |
Error on corners(%F.S): 0.2 | Temp.effect on span(F.S/10℃): 0.05 | |
Repeatariy(%F.S): 0.05 | Safe overload(%): 120 | |
Zero balance(%F.S): ±1 | Ultimate overload(%): 150 | |
Excitation voltage(VDC): 9~15 | Net weight(kg): 45 | |
Recommended voltage(V): 10 | Defend grade: IP66 |
Wireless Specification | ||
A/D conversion method | Σ-Δ 24bit | |
Input signal range | –19.5mV~19.5mV | |
Load cell excitation | DC 5V | |
Max. connection number of load cell | 1~4 | |
Load cell connection mode | 4 wire | |
Operating temperature | -10 °C ~40 °C | |
Allowable working temperature | -40 ° C ~ 70 ° C | |
Wireless transmission frequency | 430MHz to 470MHz | |
Wireless transmission distance | 800 meters (In Open Place) |
Electric forklift technology development and research direction
Application of Intrinsically Safe Explosion proof Weighing Sensor
What is the function of explosion-proof electronic weighing sensor
Why does the explosion-proof electronic scale have explosion-proof effect?
What should be paid attention to when selecting the load cell of explosion-proof scale?
0 Comment