Availability: | |
---|---|
Quantity: | |
PDF Export | |
Consulting customer service
W200 Bluetooth Module
IP Camera,Smart Home,Desktop,Set Top Box
SAINTBOND, GOLDSHINE Bluetooth Module
CN;ZHE
Bluetooth Module
Plastic
Welcome
OEM&ODM
1pcs Per type
10~15 DAYS
OEM & ODM Manufacture
Wireless networking communication equipment module W200 bluetooth module
Pin define: | ||
PIN | PIN NAME | PIN EXPLAIN |
1 | UART_TX | UART |
2 | UART_RX | UART |
3 | UART_CTS | UART |
4 | UART_RTS | UART |
5 | PCM_CLK | PCM digital audio interface, connect to the external CODEC |
6 | PCM_OUT | PCM digital audio interface, connect to the external CODEC |
7 | PCM_IN | PCM digital audio interface, connect to the external CODEC |
8 | PCM_SYNC | PCM digital audio interface, connect to the external CODEC |
9 | AIO0 | Analog input/output port |
10 | AIO1 | Analog input/output port |
11 | RESETB | System reset,low effective |
12 | VCC | Dc 3.3V |
13 | GND | GND |
14 | NC | NC |
15 | USB_D- | USB DATA- |
16 | SPI_CSB | SPI PORT ,no connect |
17 | SPI_MOSI | SPI PORT ,no connect |
18 | SPI_MISO | SPI PORT ,no connect |
19 | SPI_CLK | SPI PORT ,no connect |
20 | UB_D+ | USB DATA+ |
21 | GND | GND |
22 | GND | GND |
23 | PIO0 | Digital input/output port |
24 | PIO1 | Digital input/output port |
25 | PIO2 | Digital input/output port |
26 | PIO3 | Digital input/output port |
27 | PIO4 | Digital input/output port |
28 | PIO5 | Digital input/output port |
29 | PIO6 | Digital input/output port |
30 | PIO7 | Digital input/output port |
31 | PIO8 | Digital input/output port |
32 | PIO9 | Digital input/output port |
33 | PIO10 | Digital input/output port |
34 | PIO11 | Digital input/output port |
AT Commands:
Enter the AT command methods: power on the module ,
it is the AT model when not matching.
Interval of 1 second to send the AT command.
Default parameter: 9600, n,8,1 baud rate,
password is 1234
(1)Test communication
Send:AT (Interval of 1 second to send it)
Return:OK
(2)Change the baud of D200 module
Send:AT+RAUD1
Return:OK1200
Send:AT+RAUD2
Return:OK2400
..........
1------1200
2------2400
3------4800
4------9600(Default)
5------19200
6------38400
7------57600
8------115200
After using the AT command to set baud rate,
it will auto save them, don’t need to set it again.
(3)Change the name of bluetooth
Send:AT+NAMEname
Return:OKname
Name: new name, length<20 ascii
Eg.:Send AT+NAMEbill_gates
Return:OKname
Then the new name is bill_gates
(4)Change the password for matches
Send :AT+PINxxxx
Return:OKsetpin
Xxxx: it is the new password
(5)Change Master-slave mode
Send: AT+ROLE=M (setting module is Master)
Returns: OK+ROLE:M
Send: AT+ROLE=S (set the module is Slave ,
Default is Master)
Returns: OK+ROLE:S
(6)Set without checking
AT + PN (the default is this setting)
(7) Even parity check
AT + PE
(8)Odd parity check
AT + PO
Wireless networking communication equipment module W200 bluetooth module
Pin define: | ||
PIN | PIN NAME | PIN EXPLAIN |
1 | UART_TX | UART |
2 | UART_RX | UART |
3 | UART_CTS | UART |
4 | UART_RTS | UART |
5 | PCM_CLK | PCM digital audio interface, connect to the external CODEC |
6 | PCM_OUT | PCM digital audio interface, connect to the external CODEC |
7 | PCM_IN | PCM digital audio interface, connect to the external CODEC |
8 | PCM_SYNC | PCM digital audio interface, connect to the external CODEC |
9 | AIO0 | Analog input/output port |
10 | AIO1 | Analog input/output port |
11 | RESETB | System reset,low effective |
12 | VCC | Dc 3.3V |
13 | GND | GND |
14 | NC | NC |
15 | USB_D- | USB DATA- |
16 | SPI_CSB | SPI PORT ,no connect |
17 | SPI_MOSI | SPI PORT ,no connect |
18 | SPI_MISO | SPI PORT ,no connect |
19 | SPI_CLK | SPI PORT ,no connect |
20 | UB_D+ | USB DATA+ |
21 | GND | GND |
22 | GND | GND |
23 | PIO0 | Digital input/output port |
24 | PIO1 | Digital input/output port |
25 | PIO2 | Digital input/output port |
26 | PIO3 | Digital input/output port |
27 | PIO4 | Digital input/output port |
28 | PIO5 | Digital input/output port |
29 | PIO6 | Digital input/output port |
30 | PIO7 | Digital input/output port |
31 | PIO8 | Digital input/output port |
32 | PIO9 | Digital input/output port |
33 | PIO10 | Digital input/output port |
34 | PIO11 | Digital input/output port |
AT Commands:
Enter the AT command methods: power on the module ,
it is the AT model when not matching.
Interval of 1 second to send the AT command.
Default parameter: 9600, n,8,1 baud rate,
password is 1234
(1)Test communication
Send:AT (Interval of 1 second to send it)
Return:OK
(2)Change the baud of D200 module
Send:AT+RAUD1
Return:OK1200
Send:AT+RAUD2
Return:OK2400
..........
1------1200
2------2400
3------4800
4------9600(Default)
5------19200
6------38400
7------57600
8------115200
After using the AT command to set baud rate,
it will auto save them, don’t need to set it again.
(3)Change the name of bluetooth
Send:AT+NAMEname
Return:OKname
Name: new name, length<20 ascii
Eg.:Send AT+NAMEbill_gates
Return:OKname
Then the new name is bill_gates
(4)Change the password for matches
Send :AT+PINxxxx
Return:OKsetpin
Xxxx: it is the new password
(5)Change Master-slave mode
Send: AT+ROLE=M (setting module is Master)
Returns: OK+ROLE:M
Send: AT+ROLE=S (set the module is Slave ,
Default is Master)
Returns: OK+ROLE:S
(6)Set without checking
AT + PN (the default is this setting)
(7) Even parity check
AT + PE
(8)Odd parity check
AT + PO
Optimization Design of Diaphragm in Welding Sealed Load Sensor
Technical Characteristics and Application Analysis of Several Weighing Load Cells
High temperature weighing load cell with cylindrical spiral spring inductance coil
Analysis of the lateral load resistance ability of cantilever shear beam type weighing load cells
RC、RL The Application of Inert Circuit in the Manufacturing of Weighing Instruments and Load Cell
The role and development trend of the manufacturing process for weighing Load Cell
Electric forklift technology development and research direction
Advantages and disadvantages of resistance strain type load cell
Manufacturing link of resistance strain type weighing sensor
What are the key points for selecting explosion-proof load cells?
0 Comment